Minggu, 13 April 2014

ProComp Infiniti User Manual PDF

WARNING • Do not operate Active Sensors within 10 feet of an operating cellular phone, similar radio • All encoders are totally isolated from line (110 or 220VAC) power due to battery operation and • The PC used with ProComp Infiniti must be placed outside the patient/client environment • After use, the Disposable Electrodes may be a biohazard. Handle, and when applicable, • Radiated radio frequency electromagnetic fields can cause performance degradation in the • Explosion Hazard; Do not use in the presence of a flammable anesthetic mixture with air, or • Not to be immersed in water. transmitting device, other powerful radio interference producing sources such as arc welders, radio thermal treatment equipment, x-ray machines, or any other equipment that produces electrical sparks. fiber optic connections to computers. However, many hospitals and the FDA require that computers, printers and any other equipment used with medical devices be electrically isolated from line voltage to UL or CSA medical safety standards. (more than 3 meters or 10 feet) or the PC must comply with EN60601-1 (system safety). dispose of these materials in accordance with accepted medical practice and any applicable local, state and federal laws and regulations. • Reusable electrodes present a potential risk of cross-infection especially when used on abraded skin, unless they are restricted to a single patient or sterilized between patients. If sterilizing electrodes, employ only gas sterilization. MyoScan-Pro EMG sensor. In the worst case, an RF field strength of 22mV/M can cause an increase of 1µV in the signal reading from a MyoScan-Pro sensor. Be sure to keep in mind that a very relaxed muscle should provide an EMG reading of approximately 1-3µV. with Oxygen or Nitrous Oxide. • Take care in arranging patient and sensor cables to avoid risk of patient entanglement or strangulation. • The operator is responsible for ensuring the safety of any devices controlled or triggered by Infiniti equipment or software, or by any software or hardware receiving data from Infiniti equipment. Infiniti equipment must not be configured or connected in such a way that failure in its data acquisition, processing or control functions can trigger patient feedback stimulus that poses an unacceptable level of risk. • Use of any equipment in a biofeedback context should be immediately terminated upon any sign of treatment-related distress or discomfort. • Not to be connected to a patient undergoing MRI, Electro surgery or defibrillation.

ProComp Infiniti User Manual. www.nexgenergo.com/medical/images/SA7510Rev.3.0.pdf‎ ProComp Infiniti ™. Hardware Manual. Thought Technology Ltd. 2180 Belgrave Avenue, Montreal, QC H4A 2L8 Canada. Tel: (800) 361-3651 ٠ (514) 489-8251 .

Get The File | Type: PDF | Download here

Tidak ada komentar:

Posting Komentar